Select the catalog page:
Pag 51 - Total Hygienic gratings - Design
Image
General Catalogue #20
Catalog page
Page 51 of 60

Inoxsystem ® Total Hygienic gratings - DESIGN AND DURABILITY

IDEAL FOR SWIMMING POOLS, SHOWERS, TERRACES, LOCKER ROOMS, PUBLIC AREAS

Inoxsystem® Total Hygienic Design and Multi-slot Design gratings are ideal for swimming pools, terraces, changing rooms, Spa, hotels, public facilities as well as for pharmaceutical and industrial plants. Their frameless design ensures the highest standards of hygiene and the care of details makes them a perfect mix of elegance and functionality where modern design is required. Tileable Design grating is also available.

DESIGN

Channel 5001 with grating G0874
Total Hygienic DESIGN grating - satin finished
closed grating with TWO SIDE SLOTS OF 5 mm
h 20 mm, frameless design
ANTISEPTIC - LIGHT DUTY
LOAD CLASS A15
Width
C
Length
D
Grating
B
Slots
(C-B)/2
Spacers
A
65 1000 (max) 57 4 500
* Design grating 0874 available on request
Other patterns available on request (see IDrain catalogue)
Channel 5001 with grating G0874
Total Hygienic DESIGN grating - satin finished
closed grating with TWO SIDE SLOTS OF 5 mm
h 20 mm, frameless design
ANTISEPTIC - LIGHT DUTY
LOAD CLASS A15
Width
C
Length
D
Grating
B
Slots
(C-B)/2
Spacers
A
65 1000 (max) 57 4 500
* Design grating 0874 available on request 
Other patterns available on request (see IDrain catalogue)

MULTI-SLOT DESIGN

Channel 5001 with grating G0875
Total Hygienic MULTI-SLOT DESIGN grating,
frameless design, mesh 8x160 mm h 20 mm
ANTISEPTIC
MEDIUM DUTY
LOAD CLASS B125
Width
C
Length
D
Mesh
AxB
Bearing bar
HxS
Cross bar
BxH1
65 1000 (max) 10x160 20x4 10x4
* Design grating 0875 available on request
Channel 5001 with grating G0875
Total Hygienic MULTI-SLOT DESIGN grating,
frameless design, mesh 8x160 mm h 20 mm
ANTISEPTIC
MEDIUM DUTY
LOAD CLASS B125
Width
C
Length
D
Mesh
AxB
Bearing bar
HxS
Cross bar
BxH1
65 1000 (max) 10x160 20x4 10x4
* Design grating 0875 available on request
By removing both filter basket and internal pipe the wastewater flows and the floor drain should be thoroughly cleaned.
It is highly recommended to fill the floor drain with water after cleaning in order to stop smells from coming back up.

Total Hygienic gratings design in stainless steel


PRODUCTS